Used Cremer 1230 12-lane Tablet Counter, Model CF1230-S006, Serial 873200DA, 220/60/3, built 1993. The Cremer CF-1230 is a 12-channel linear tablet and capsule counter, counts any kind of tablet, hard or softgel capsule. Includes bulk hopper with gate, linear vibratory plates for optimal product separation, 12-channel detection unit, and (2) filling nozzles with dust collection port with Operational Manual included
Specifications:
- Counter: Count Value
- Precount: Count value -30 (Max:100)
- Start Seperation Speed: Count value -30
- Counting speed: See how produvt reacts on plate(front)
- Separations Speed: Counting speed -10
- Hopper: 90
- Hopper Frequency: Adjust it so it will not overfill the front plate
- Hopping time: Value between 4 and 6
- Rejection/min: 2
- Nozzle vibration: 0, No vibration 4: vibration
- Counting Mode: 0 counts higher than 10, 1: count lower than 10
- Count Sensor delay: Set at 0, unless machine is doing undercounts(rotating Products)
- Product width: Smallest product width- 1 mm
- Container size: Size of container for indexing purpose